SUN-12K-SG04LP3-EU Hybrid Inverter

100% unbalanced output, each phase;
Max. output up to 50% rated power
AC couple to retrofifit existing solar system
Max. 10 pcs parallel for on-grid and off-grid operation;
Support multiple batteries parallel
Max. charging/discharging current of 240A
Support storing energy from diesel generator
48V low voltage battery, transformer isolation design
6 time periods for battery charging/discharging
Quantity
ADD TO CART
BUY IT NOW
Detail

Description

 Model  SUN-5K-SG04LP3-EU  SUN-6K-SG04LP3-EU  SUN-8K-SG04LP3-EU  SUN-10K-SG04LP3-EU  SUN-12K-SG04LP3-EU
 Battery Input Data
 Battery Type  Lead-acid or Lithium-ion
 Battery Voltage Range(V)  40-60
 Max.Charging Current(A) 120 150 190 210 240
 Max.Discharging Current(A) 120 150 190 210 240
 Charging Strategy for Li-ion Battery  Self-adaption to BMS
 Number of battery input 2
 PV String Input Data
 Max DC Input Power(W) 6500 7800 10400 13000 15600
 Max DC Input Voltage(V) 800
 Start-up Voltage(V) 160
 MPPT Voltage Range(V)  200-650
 Rated DC Input Voltage(V) 550
 Max. Operating PV Input Current (A)  13+13  26+13
 Max. Input Short-Circuit Current (A)  17+17  34+17
 No.of MPP Trackers/No.of String Per MPP Tracker  2/1+1  2/2+1
 AC Input/Output Data
 Rated AC Input/Output Active Power(W) 5000 6000 8000 10000 12000
 Max AC Input/Output Apparent Power (VA) 5500 6600 8800 11000 13200
 Peak Power (off-grid)(W)  2 times of rated power, 10s
 Rated AC Input/Output Current(A)  7.6/7.2  9.1/8.7  12.1/11.6  15.2/14.5  18.2/17.4
 Max AC Input/Output Current(A)  8.4/8  10/9.6  13.4/12.8  16.7/15.9  20/19.1
 Max. Three-phase Unbalanced Output Current(A)  11.4/10.9  13.6/13  18.2/17.4  22.7/21.7  27.3/26.1
 Max Continuous AC Passthrough (grid to load)(A) 45
 Rated Input/Output Voltage/Range(V)  220/380V,230/400V 0.85Un-1.1Un
 Grid Connection Form  3L+N+PE
 Rated Input/Output Grid Frequency/Range  50/45-55, 60/55-65
 Power Factor Adjustment Range  0.8 leading to 0.8 lagging
 Total Current Harmonic Distortion THDi  <3% (of nominal power)
 DC Injection Current  <0.5%ln
 Efficiency
 Max Efficiency 97.60%
 Euro Efficiency 97.00%
 MPPT Efficiency  >99%
 Equipment Protection
 DC Polarity Reverse Connection Protection  YES
 AC Output Overcurrent Protection  YES
 AC Output Overvoltage Protection  YES
 AC Output Short Circuit Protection  YES
 Thermal Protection  YES
 DC Terminal Insulation Impedance Monitoring  YES
 DC Component Monitoring  YES
 Ground Fault Current Monitoring  YES
 Power Network Monitoring  YES
 Island Protection Monitoring  YES
 Earth Fault Detection  YES
 DC Input Switch  YES
 Overvoltage Load Drop Protection  YES
 Residual Current (RCD) Detection  YES
 Surge Protection Level  TYPE II(DC), TYPE II(AC)
 Interface
 Communication Interface  WIFI, RS485, CAN
 General Data
 Operating Temperature Range  -40 to +60℃, >45℃ Derating
 Permissible Ambient Humidity  0-100%
 Permissible Altitude  2000m
 Noise  ≤ 55 dB(A)
 Ingress Protection(IP) Rating  IP 65
 Inverter Topology  Non-Isolated
 Over Voltage Category  OVC II(DC),OVC III(AC)
 Cabinet size(W*H*D)[mm]  422×658×254(Excluding connectors and brackets)
 Weight[kg] 38
 Warranty  5 Years/10 Years
 the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
 Type Of Cooling  Intelligent air cooling
 Grid Regulation  IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
 OVE-Richtlinie R25, G99, VDE-AR-N 4105