SUN-12K-SG04LP3-EU Hybrid Inverter
100% unbalanced output, each phase;
Max. output up to 50% rated power
AC couple to retrofifit existing solar system
Max. 10 pcs parallel for on-grid and off-grid operation;
Support multiple batteries parallel
Max. charging/discharging current of 240A
Support storing energy from diesel generator
48V low voltage battery, transformer isolation design
6 time periods for battery charging/discharging
Max. output up to 50% rated power
AC couple to retrofifit existing solar system
Max. 10 pcs parallel for on-grid and off-grid operation;
Support multiple batteries parallel
Max. charging/discharging current of 240A
Support storing energy from diesel generator
48V low voltage battery, transformer isolation design
6 time periods for battery charging/discharging
Quantity
Detail
Description
Model | SUN-5K-SG04LP3-EU | SUN-6K-SG04LP3-EU | SUN-8K-SG04LP3-EU | SUN-10K-SG04LP3-EU | SUN-12K-SG04LP3-EU |
Battery Input Data | |||||
Battery Type | Lead-acid or Lithium-ion | ||||
Battery Voltage Range(V) | 40-60 | ||||
Max.Charging Current(A) | 120 | 150 | 190 | 210 | 240 |
Max.Discharging Current(A) | 120 | 150 | 190 | 210 | 240 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS | ||||
Number of battery input | 2 | ||||
PV String Input Data | |||||
Max DC Input Power(W) | 6500 | 7800 | 10400 | 13000 | 15600 |
Max DC Input Voltage(V) | 800 | ||||
Start-up Voltage(V) | 160 | ||||
MPPT Voltage Range(V) | 200-650 | ||||
Rated DC Input Voltage(V) | 550 | ||||
Max. Operating PV Input Current (A) | 13+13 | 26+13 | |||
Max. Input Short-Circuit Current (A) | 17+17 | 34+17 | |||
No.of MPP Trackers/No.of String Per MPP Tracker | 2/1+1 | 2/2+1 | |||
AC Input/Output Data | |||||
Rated AC Input/Output Active Power(W) | 5000 | 6000 | 8000 | 10000 | 12000 |
Max AC Input/Output Apparent Power (VA) | 5500 | 6600 | 8800 | 11000 | 13200 |
Peak Power (off-grid)(W) | 2 times of rated power, 10s | ||||
Rated AC Input/Output Current(A) | 7.6/7.2 | 9.1/8.7 | 12.1/11.6 | 15.2/14.5 | 18.2/17.4 |
Max AC Input/Output Current(A) | 8.4/8 | 10/9.6 | 13.4/12.8 | 16.7/15.9 | 20/19.1 |
Max. Three-phase Unbalanced Output Current(A) | 11.4/10.9 | 13.6/13 | 18.2/17.4 | 22.7/21.7 | 27.3/26.1 |
Max Continuous AC Passthrough (grid to load)(A) | 45 | ||||
Rated Input/Output Voltage/Range(V) | 220/380V,230/400V 0.85Un-1.1Un | ||||
Grid Connection Form | 3L+N+PE | ||||
Rated Input/Output Grid Frequency/Range | 50/45-55, 60/55-65 | ||||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||
DC Injection Current | <0.5%ln | ||||
Efficiency | |||||
Max Efficiency | 97.60% | ||||
Euro Efficiency | 97.00% | ||||
MPPT Efficiency | >99% | ||||
Equipment Protection | |||||
DC Polarity Reverse Connection Protection | YES | ||||
AC Output Overcurrent Protection | YES | ||||
AC Output Overvoltage Protection | YES | ||||
AC Output Short Circuit Protection | YES | ||||
Thermal Protection | YES | ||||
DC Terminal Insulation Impedance Monitoring | YES | ||||
DC Component Monitoring | YES | ||||
Ground Fault Current Monitoring | YES | ||||
Power Network Monitoring | YES | ||||
Island Protection Monitoring | YES | ||||
Earth Fault Detection | YES | ||||
DC Input Switch | YES | ||||
Overvoltage Load Drop Protection | YES | ||||
Residual Current (RCD) Detection | YES | ||||
Surge Protection Level | TYPE II(DC), TYPE II(AC) | ||||
Interface | |||||
Communication Interface | WIFI, RS485, CAN | ||||
General Data | |||||
Operating Temperature Range | -40 to +60℃, >45℃ Derating | ||||
Permissible Ambient Humidity | 0-100% | ||||
Permissible Altitude | 2000m | ||||
Noise | ≤ 55 dB(A) | ||||
Ingress Protection(IP) Rating | IP 65 | ||||
Inverter Topology | Non-Isolated | ||||
Over Voltage Category | OVC II(DC),OVC III(AC) | ||||
Cabinet size(W*H*D)[mm] | 422×658×254(Excluding connectors and brackets) | ||||
Weight[kg] | 38 | ||||
Warranty | 5 Years/10 Years | ||||
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | |||||
Type Of Cooling | Intelligent air cooling | ||||
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, | ||||
OVE-Richtlinie R25, G99, VDE-AR-N 4105 | |||||
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |